http:ReadManm FINAL DRIVEJET PUMPBILGE SYSTEM Pump To Hull Alignment 3Grease the large pump sealing O-ring and apply Marine
steps to 28 ftIbs(38.7 Nm)Tighten 28 ftIbs(38.7 Nm) 5Torque pump mounting nuts (outside of hull) evenly in three steps to
28 ftIbs(38.7 Nm) using criss cross patternCheck to be sure pump housing is tight against hullTo inspect pump-to-hull fit,
measure the gap between the hull and pump housing with feeler gaugeIf gap is present it should not exceed .010" (.25mm)Check