http:ReadManm ELECTRICAL Battery Testing Specific Gravity Test A tool such as the battery hydrometer can be used to measure
Charged 25 Charged Charged CONVENTIONAL LEAD-ACID 1.265 1.210 1.160 1.120 less than 1.100 YUMICRON TYPE 1.275 1.225 1.175
1.135 less than 1.115 Detail A At 80F NOTE: Subtract .01 from the specific gravity reading at 40 F Load Test A battery may
indicate full charge condition in the OCV test and the specific gravity test, but still not have the storage capacity necessary
to properly function in the electrical systemFor this reason battery capacity or load test should be conducted whenever poor
battery performance is encounteredNOTE: This test cannot be performed with an engine or starting system that is not working
properly Attach multitester to the batteryThe reading should be 12.4 volts or greaterEngage electric starter and view registered
battery voltage while cranking engineContinue the test for 15 secondsDuring this cranking period, the observed voltage should