2000 Polaris Virage TX, SLX, Pro 1200, Genesis, Genesis FFI Personal Watercraft Service Manual, Page 233Get this manual

2000 Polaris Virage TX, SLX, Pro 1200, Genesis, Genesis FFI Personal Watercraft Service Manual, Page 233

http:ReadManm ELECTRICAL Battery Maintenance Refilling Low Battery The normal chargedischarge cycle of battery causes the
if necessaryCharge at rate no greater than 110 of the battery's amphr capacity until the electrolyte's specific gravity reaches
1.270 or greaterStore battery either in machine with cables disconnected, or store in cool dry placeNOTE: Stored batteries
lose their charge at the rate of per dayThey should be recharged to full charge every 60 to 90 days during non-use periodIf
stored during the winter months, the electrolyte will freeze at higher temperature as the battery dischargesThe chart below
indicates freezing points by specific gravityELECTROLYTE FREEZING POINTS Specific Gravity of Electrolyte 1.265 1.225 1.200
1.150 1.100 1.050 Freezing Point -75F -35F -17F +5 +18F +27F Charging Procedure Charge the battery with charger no larger
than 110 of the battery's amphr rating for as many hours as needed to raise the specific gravity to 1.270 or greater WARNING
The gases given off by battery are explosiveAny spark or open flame near battery can cause an explosion which will spray