http:ReadManm ELECTRICAL Electric Starter Testing Electric Starter System Testing Condition: Starter fails to turn motor
both sides of the start switch with the switch on startRepair or replace any defective part(s)! Reconnect the solenoidConnect
the tester black lead to the battery positive terminal and the red tester lead to the solenoid end of the battery-to-solenoid
cablePush the start buttonThe reading must be less than .1 DCIs it? Clean the battery to solenoid cable ends or replace the
cable Vest Connect the black tester lead to the solenoid end of the battery-to-solenoid cable and the red tester lead to
the solenoid end of the solenoid-to-starter cablePush the start buttonThe reading must be less than .1 DCIs it? Replace the
starter solenoid Connect the black tester lead to the solenoid end of the solenoid-to-starter cable and the red tester lead
to the starter end of the same cablePush the start buttonThe reading must be less than .1v DCIs it? Clean the solenoid-to-starter