http:ReadManm FFI1M FUEL INJECTION Preliminary Tests Since electrical, fuel, and ignition systems interact, symptom can have
wires on the Genesis FFI1M Check circuit breakersGo to Diagnostic Guide Step 5: If engine will crank but not start, eliminate
the stop switch first by testing the black and yellow wires that lead to the stop switchIf okay, perform cranking spark test
with timing lightResults: Steady spark on allfault is in fuel or electrical systemGo to Step 6No sparktest battery for full
chargeNo sparkInspect starterCheck for too much voltage dropSee Electrical SectionNo spark on some or allnote problem cylindersGo
to appropriate symptom in Diagnostic Guide Step 6: If engine will run, perform the following tests (while problem is occurring,
if possible)NOTE: Polaris Diagnostic Software is able to perform cylinder drop tests, as well as provide live engine data,
and should be used with the following proceduresA: Monitor each spark plug lead with timing lightLook for only one flash