Maintenance EngineContinued Exhaust Cooling OrificeScreen Cleaning The exhaust pipe rubber hoses and muffler are cooled by
clamp connecting hose to fitting and remove lineUsing deep well 9 16" socket or flare nut wrenchremove fitting from exhaust
manifold Inspect fitting for debris or restriction and clean if necessaryInspect and clean orifice and screen Periodic inspection
and cleaning of this screen is required for proper cooling performance4Apply pipe thread sealant to threads of fitting and
re-installTighten securely5Re-install air bypass hose and tighten clamp Orifice Size: 700s .055" (1.4m m) Exhaust Pipe Exhaust