Final DrivePropulsion Pump Alignment- SLHVirageContinued Th pump must be mounted flush with the hull and intake scoop to
.010" (.25mm)Pump-to-hull misalignment can be caused by: Improperly installed intake scoop (check ride plateit should be
flush with bottom of hull)Improperly installed studs or damage to the hexagonal recess in housing (see page 5.28) Hull damaged
in pump mounting areaDamage to hull may result if pump mounts are over-tightened (often due to the use of air tools), or
if studs are improperly installed in pumpIf the hex portion of the stud is not engaged properly in the pump housing recess,
the hex portion of the stud may protrude past the edge of the pump housing, and prevent the housing from seating fully against