2001 Polaris SLX, PRO 1200, Virage TX, Genesis, Virage TXi, Genesis i Personal Watercraft Service Manual, Page 262

Electrical Systems 2001 RPM Limiter Systems Model Genesis Genesis Virage TXi Virage PRO 1200 SLX Temperature Sensor "ON"
the COl senses the ground path connection and activates the limiting functionSee diagram belowImportant Note: When the engine
overheat circuit has caused the system to limit, it will continue to limit until both of the following conditions are met:
12The problem that caused the initial limiting must be corrected (cool engine); The operator must momentarily release the
throttle and allow the RPM to fall below 3500 Carbureted Models Only Electrical Box COl Unit Multi-Function Display Terminal
Board Thermal Switch (on engine) When limiter circuit is activated engine RPM will be limited to 3500i= NOTE: The EMM on
Polaris DFI 1M models activates the RPM limiter at 3500 RPM Reverse RPM Limiters The 2001 Virage TX will limit RPM at 3500