Electrical Systems MFD MFI Troubleshooting t the MFDMFI is not working check the following items: Battery connections for
minute to reset the microprocessorWhen reconnecting the battery negative cable, take care to make it as "clean" connection
as possibleOnly contact the battery terminal once while connecting the cableDo not contact the terminal repeatedlyHold pressure
on the cable until the terminal bolt is tight To avoid the possibility of explosion, always disconnect the negative cable
first and connect it last One part of display malfunctionsDetermine which function (or functions) are not workingIf only
one or two parts of the display are affected, chances are the input for that function is the problemTest individual senders
and inputs including related wiringRefer to the electrical wiring diagramCheck for clean, tight connections at the back of
the gauge and inside the electrical boxIf water is present in the electrical box, be sure the wire sealing grommets and box
sealing a-ring are properly positionedRoute wires carefully when assembling the box to prevent pinched wiresOn new units,