Electrical Systems MFI Compass Calibration The electronic compass provides eight points of heading informationIts solid-state
location changes significantly, or if the battery is disconnectedNOTE: It is important that the watercraft is floating and
away from any large metal objects or magnetic sources at the time of calibration1Press the MODE button until ENGINE HOUR
is displayed2Press SET for approximately seconds until CC SET is displayed3Carefully align and hold the watercraft in any
direction4Press the SET keyThe display will now read SET 25Again, carefully rotate the watercraft 180 and face it in the
opposite direction6Press the SET keyThe MFI will use these two readings to calculate the proper calibration and store it