Final DrivePropulsion Bearing Housing RemovalInspectionContinued 2Inspect bushings and seals in bearing housing assembly
of metal parts due to electrolysisThe mounting surfaces must be clean and the mounting bolt tight to maintain good connection
between the pump and anode1Periodically inspect anode for excessive wear2Check bolt to be sure it is tightIf the bolt is
loose, remove anode and clean mounting surfaces on pump and anode3Apply dielectric grease to bolt threads and contact surfaces4Tighten
bolt securelyNOTE: During preventative maintenance, verify that the anode is tightened securely to the pump housingReplace