2004 Polaris Freedom, Virage, Genesis and MSX-140 Service Manual., Page 30Get this manual

2004 Polaris Freedom, Virage, Genesis and MSX-140 Service Manual., Page 30

MAINTENANCE Electrical ComponentsContinued Replenishing Battery Fluid The fluid level should be kept between the upper and
could ignite them which could cause personal injuryWhen re-installing battery connect black (negative) cable lastWARNING
Keep the battery away from sparks and open flames during charging because the battery gives off gases which are explosiveIf
you smell fuel do not attempt to charge the batteryWhen using battery charger connect the battery to the charger before turning
on the chargerThis prevents the possibility of sparks at the terminals which could ignite the battery gasesDo not connect
charger cables to the battery unless the charger is unplugged1Remove caps from cellsAdd distilled water if necessary to bring
electrolyte up to proper level2Connect battery to chargerSet charging rate at 1.9 amps (maximum) and charge battery for ten
hoursCAUTION: During charging, if the electrolyte temperature rises above 115 (45 C) or if battery feels hot when touched,
reduce the charging rate to lower the temperature and increase the charging time3After battery is charged, check fluid levelIf