PROPULSION Pump Assembly (Genesis i) STUB SHAFT PUMP STATOR WATER PIPE IMPELLER PUMP HOUSING ANODE STEERING NOZZLE WEDGE
2nd Step: 14 ft.lbs(2.719 Nm) Steering Nozzle Fastener Torque: 14 ft.lbs(19 Nm) Apply Loctitet 242Reverse Nozzle Fastener
Torque: 14 ft.lbs(19 Nm) Apply Loctitet 242Thruhull lock plate must be installed with flat against steering cable thruhull
nutApply antiseize to pump component mating surfacesApply premium grease to orings prior to assemblyPump assembly must be
flush against hull to prevent leakage or ventilationApply liberal amount of marine-grade silicone to mating surfacesVerify