ELECTRICAL SYSTEMS RPM Limiter Systems Model Freedom 16071 Virage Virage Genesis MSX 140 EMM Controlled Temperature Sensor
engine overheat circuit has caused the system to limit, it will continue to limit until both of the following conditions
are met: 1The problem that caused the initial limiting must be corrected (cool engine); AND 2The operator must momentarily
release the throttle and allow the RPM to fall below 3500 Reverse RPM Limiters The following watercraft will limit in reverse
mode: Genesis PERCt PERCtPolaris Electronic Reverse Control The Virage, Virage i, and MSX 140 use manual reverse systemWhen
the reverse lever is engaged in either neutral or reverse, switch is contacted, putting the CDI, or EMM in limiting modeThe
Genesis will limit RPM whenever the reverse control thumbpad is pressed in either neutral or reverseNOTE: The CDI or EMM