Section 07 ELECTRICAL Sub-section 03 (BATTERY) SERVICING Electrolyte Level Since battery has been activated (see above),
hours after charging begunDo not charge frozen battery if the battery charge is very Sow, the battery may freezeIf it is
suspected to be frozen, keep it in heated area for about hours before charging - Exceptionally for this particular case,
set the charger to high rate NOTESome chargers have polarity protection feature which prevents charging unless the charger
leads are connected to the correct battery terminalsA completely chscharged battery may not have enough voltage to activate
this circuitry, even though the leads are connected properlyThis wili make it appearthat the battery will not accept charge
Follow the charger manufacturer's instruction on how to bypass or override this circuitry so that the charger will turn on
and charge low-voltage battery WARNINGDo not place battery near open flameThe time required to charge battery will vary dependu-ig
on some factors such as - Battery temperatureThe charging time is increased as the temperature goes downThe curlrent accepted