2003-2004 GP1300R WaveRunner Service Manual, Page 95Get this manual

2003-2004 GP1300R WaveRunner Service Manual, Page 95

Quality of the image is intentionally reduced!

COMPRESSION PRESSURE MEASUREMENT
6 Measure: Compression pressure Out of specification Refer to steps (b) and (c)Minimum compression pressure (reference data): 640 kPa (6.4 kgfcm2, 91 psi) Measur