2006-2008 Yamaha RS, Vector, Rage Factory Service Manual, Page 62Get this manual

2006-2008 Yamaha RS, Vector, Rage Factory Service Manual, Page 62

BATTERY INSPECTION INSP ADJ First aid in case of bodily contact: External SKIN Wash with water EYES Flush with water for
and charging voltage for MF battery are different from those of conventional batteriesThe MF battery should be charged as
explained in the charging method illustrationsIf the battery is overcharged, the electrolyte level will drop considerablyTherefore,
take special care when charging the battery Since MF batteries are sealed, it is not possible to check the charge state of
the battery by measuring the specific gravity of the electrolyteTherefore, the charge of the battery has to be checked by